The B705 converter is a transmitter which can be placed in the field close
to the Zirconia probe. The converter receives the signal from the Zirconia cell and from the compensation and regulation thermocouple which is fitted
inside the probe (type K). The converter can be connected with any FER mod.
5175 or 5185 low temperature probe. Based on a microprocessor associated to an
analogical-digital converter (12 bit) is equipped with a led display 3 ½;
digit, which shows continuously the percentage of oxygen in volume on which is
possible, by depressing a push button, to show the temperature of the heated
probe from the compensation and regulation thermocouple and the impedance of
the zirconia measuring element. The converter is equipped with an analogical
output 4-20 mA or 0-10 Volts, linear and proportional to 0-25% and 0-10%,
0-5% and 0-2000 ppm oxygen content.
Four oxygen fields are selectable from the instrument. The converter can
be optionally equipped with the pneumatic part (pressure reducer or electric
pump) to deliver to the probe reference air and calibration air and gas. The
electronic converter, display and pneumatic device are housed in a strong
water proof metal box (IP55).
Technical specifications
-
Input: zirconia cell and compensation and regulation thermocouple
-
Measuring field: oxygen 0,0001÷25% in volume
-
Accuracy of the converter: ± 1% of
Full range
-
Display: 3½ digit
-
Analogical output: 4-20 mA galvanically isolated linear on 4 oxygen field:
0,0 - 25% O2
0,0 - 10% O2
0,0 - 5% O2
10 - 2000 ppm O2
-
Dumper time constant adjustable within 0 and
999 seconds.
-
Alarms: oxygen high and low settable on a field of 0,0 -
25% with
resolution 0,1%.Fault and Service alarm
-
Fail-safe: if the signals from the
Zirconia cell or from the
thermocouple fails, the current output will go to 2 mA and the
status alarm deenegized.
-
Power: 230 and 110 VAC 50/60 Hz 250 W max
-
Housing: water proof metal box IP 55 - 300 x 400 x 500 mm
-
Weight: kg 11
|