FGMS

for CO, NOx, O2, TOC, Dust measurement

  • Measured compounds
    • CO – Carbon monoxide – Infrared analyzer Mod. Enox II
    • NOx – Nitrogen oxides – Infrared analyzer Mod. Enox II and NO2/NO molybdenum based converter
    • TOC – Total organic carbons – Flame ionization analyzer – FID
    • Dust – with triboelectric analyzer
    • O2 – Oxygen – Analyzer with zirconium oxide cell Mod. E705
  • Sampling and treatment system
    n.1 Probe with heated filter, n.1 Heated line, Compressor based gas cooler, n. 1 Sampling pump, Condensate monitor, Flowmeter
  • Monitored plant
    Aluminum recovery furnace emissions
  • Cabinet
    • Painted metal sheet with air conditioner for temperatures up to 55 °C
    • IP54 protection degree
  • Data processing
    Modbus output and data acquisition with DAS-DAC system: remote control for technical assistance