FGMS

for CO, NOx, SO2, CO2, O2 measurement

  • Measured compounds
    • CO – Carbon monoxide – Infrared analyzer Mod. Enox II
    • NOx – Nitrogen oxides – Infrared analyzer Mod. Enox II and NO2/NO molybdenum based converter
    • SO2 – Sulfur dioxide – Infrared analyzer Mod. Enox II
    • CO2 – Carbon dioxide – Infrared analyzer Mod. Methox
    • O2 – Oxygen – Analyzer with zirconium oxide cell Mod. E705
  • Sampling and treatment system
    n. 1 Probe with heated filter, n.1 Heated line, Compressor based gas cooler, n. 1 Sampling pump, Condensate monitor, Flowmeter
  • Monitored plant
    Furnace emissions from heating in Egypt
  • Cabinet
    • Painted metal sheet with air conditioner for temperatures up to 55 °C
    • IP54 protection rating
  • Data processing
    • 5 x 4-20 mA analog outputs
    • 10 x Relay outputs for alarms and signals